Mains Voltage Socket Outlet Assemblies to BS EN 60309-2, rated 16A to 63A, with integral RCD, MCB or Monitored Earth Protection
SafePower - RCD and Monitored Earth Equipment
Protection
-
-
RCD protected socket outlets; rated at 16A, 32A or 63A; 230V or 400V; 3P, 4P or 5P; surface mounting insulated enclosure.
-
RCD protected socket outlets with the addition of MCB protection; rated at 16A, 32A or 63A; 230V or 400V; 3P, 4P or 5P; surface mounting insulated enclosure.
-
RCD and Monitored Earth protected socket outlets; rated at 16A, 32A or 63A; 230V or 400V; surface mounting insulated enclosure.
-
RCD and Monitored Earth protected socket outlets with the addition of MCB protection; rated at 16A, 32A or 63A; 230V or 400V; surface mounting insulated enclosure.
-
RCD Assemblies with overcurrent protection in ratings from 1A to 2000A, single or three phase, housed in steel or insulated enclosures.
-
Earth leakage protection assemblies with overcurrent protection, rated from 100A to 1250A, 4P, housed in IP55, all insulated enclosures
-
Earth leakage protection assemblies with overcurrent protection, rated up to 100A, DP or TP&N, housed in IP30, steel enclosures. All models are classified as Network Rail "DC Immune".
-
Earth leakage protection assemblies with overcurrent protection, rated from 100A to 800A, TP&N, housed in IP54, steel enclosures
-
Safe Supply Units protect 230V sockets in school science laboratories.
SSUs provide the highest level of protection against electric shock and incorporate a 1:1 ratio transformer, 1.25mA or 5mA RCD protection and a current limiting resistor which restricts the maximum level of earth leakage to 10mA at all times.
-
Safe Supply Unit in floor standing console style enclosure, 3 or 5 kVA rating, 1.25mA or 5mA sensitivity, 3 no. outgoing DP MCBs.
There is a FAQ sheet about Safe Supply Units in the Technical Data Sheets section of Product Data.
-
Safe Supply Unit in floor standing enclosure, 5, 8 or 10 kVA rating, 1.25mA or 5mA sensitivity, option of 2, 3 or 4 outgoing DP MCB ways.
There is a FAQ sheet about Safe Supply Units in the Technical Data Sheets section of Product Data.
-
Safe Supply Unit in wall mounting enclosure, 2 or 3 kVA rating, 1.25mA or 5mA sensitivity, option of 2 or 3 outgoing DP MCB ways
There is a FAQ sheet about Safe Supply Units in the Technical Data Sheets section of Product Data.
-
ECMs are devices that work in combination with contactors or circuit breakers to help ensure portable equipment is always effectively earthed. ECMs are incorporated into our Monitored Earth protection assemblies and they can be purchased by OEMs for incorporation into specialist assemblies.
-
Core balance earth leakage sensors with fixed and variable sensitivity to work in conjunction with circuit breakers and contactors to provide RCD protection
-
Loose ELS sensors for use as spares or for purchase by OEMs for incorporation into their own assemblies.
-
Loose VELS sensors for use as spares or for purchase by OEMs for incorporation into their own assemblies.
-
Loose VRCD sensors with matched CTs for use as spares or for purchase by OEMs for incorporation into their own assemblies.
-
Loose VELR sensors and CTs for use as spares or for purchase by OEMs for incorporation into their own assemblies.
-
RCD and Monitored Earth protected socket outlet, 32A 400V 6 pin, with the addition of MCB protection, surface mounting steel enclosure.
-
Earth leakage protection assemblies, from 1A to 2000A rating, single and three phase with sensitivities ranging from 5mA to 300A, made to order.
Please complete the detailed Enquiry Form, forward it to us and we will quote you as quickly as possible. Alternatively, click on Quick Enquiry, forward your details and we will contact you to discuss your requirements.
-
Variable Laboratory Supply Units provide AC and DC (smoothed or unsmoothed) outputs enabling electrical experiments to be carried out at a range of Extra Low Voltages.
If you require a quotation for VLSUs, please click Quick Enquiry and either upload your specification and forward it to us or just forward your contact details and we will contact you by return to discuss your requirements.
-
In addition to the standard models detailed on the website, non-standard models can be supplied.
If you require a quotation for a non-standard SSU, please click Quick Enquiry and either upload your specification and forward it to us or just forward your contact details and we will contact you by return to discuss your requirements.
There is a FAQ sheet about Safe Supply Units in the Technical Data Sheets section of Product Data.
Transformers
-
Safe Supply Units protect 230V sockets in school science laboratories.
SSUs provide the highest level of protection against electric shock and incorporate a 1:1 ratio transformer, 1.25mA or 5mA RCD protection and a current limiting resistor which restricts the maximum level of earth leakage to 10mA at all times.
-
Safe Supply Unit in floor standing console style enclosure, 3 or 5 kVA rating, 1.25mA or 5mA sensitivity, 3 no. outgoing DP MCBs.
There is a FAQ sheet about Safe Supply Units in the Technical Data Sheets section of Product Data.
-
Safe Supply Unit in floor standing enclosure, 5, 8 or 10 kVA rating, 1.25mA or 5mA sensitivity, option of 2, 3 or 4 outgoing DP MCB ways.
There is a FAQ sheet about Safe Supply Units in the Technical Data Sheets section of Product Data.
-
Safe Supply Unit in wall mounting enclosure, 2 or 3 kVA rating, 1.25mA or 5mA sensitivity, option of 2 or 3 outgoing DP MCB ways
There is a FAQ sheet about Safe Supply Units in the Technical Data Sheets section of Product Data.
-
In addition to the standard models detailed on the website, non-standard models can be supplied.
If you require a quotation for a non-standard SSU, please click Quick Enquiry and either upload your specification and forward it to us or just forward your contact details and we will contact you by return to discuss your requirements.
There is a FAQ sheet about Safe Supply Units in the Technical Data Sheets section of Product Data.