Construction Site Transformers

Slim Line Power & Lighting Transformer with RCD & MCB Protection

Type Ref: TA-SL/P/3/7.5/RCD-S6/C2-RCD

7.5kVA icon Continuous rating icon 3 phase icon Power and Lighting icon RCD icon

£1110.00

Can’t find what you’re looking for?

We’re always here to help! Give us a call or fill out our contact form and a member of our team will be in touch!

Slim line site transformer, 7.5kVA three-phase, 400:110NE, 4 x 16A and 2 x 32A 110V sockets group protected by a 300mA* sensitivity 4P RCD. Also fitted 2 x 10A 30mA RCBOs to supply lighting circuits.
*In early 2024 we will start fitting RCCBs with a 100mA sensitivity instead of a 300mA sensitivity. During the transition period you may receive a transformer fitted with an RCCB of either sensitivity.

Slim Line Site Power and Lighting Transformer, 7.5kVA three-phase, developed for locations where space on site is at a premium. Manufactured in accordance with the requirements of BS4363.

Enclosure
Robust, compact, free-standing, non-vented enclosure of welded sheet steel construction, incorporating certified lifting handles. The enclosure provides protection to IP44 and has a durable, oven dried polyester powder coated finish, shade Traffic Yellow.
Enclosure Dimensions: 600W x 285D x 670H (plus lifting handle and socket protrusions to the top and sides).

Rating
7.5 kVA three-phase, continuously rated

Primary Volts
400 delta connection

Primary Protection
10A TP Type “D” MCB

Secondary Volts
110NE providing a Reduced Low Voltage (RLV) supply

Distribution
1 no. 63A 4P 110V 300mA* Type A RCCB feeding: 4 no. 16A DP Type “C” MCBs each feeding a 16A 2P+E 110V IP44 socket; and 2 no. 32A DP Type “C” MCBs each feeding a 32A 2P+E 110V IP44 socket.
Also fitted with 2 no. 10A DP 110V RCBOs providing C curve MCB protection and Type A RCD protection, each feeding a 3 way terminal block for direct connection to lighting circuits (the lighting connections can be made without removing the transformer lid). The incorporation of RCD protection ensures compliance with disconnection times on longer lighting circuits with a high Zs.
*In early 2024 we will start fitting RCCBs with a 100mA sensitivity instead of a 300mA sensitivity. During the transition period you may receive a transformer fitted with an RCCB of either sensitivity.